The early symptoms of untreated diabetes are related to elevated blood sugar levels, and loss of glucose in the urine. High amounts of glucose in the urine can cause increased urine output and lead to dehydration. Dehydration causes increased thirst and water consumption.
The inability of insulin to perform normally has effects on protein, fat and carbohydrate metabolism. Insulin is an anabolic hormone, that is, one that encourages storage of fat and protein.
A relative or absolute insulin deficiency eventually leads to weight loss despite an increase in appetite.
Some untreated diabetes patients also complain of fatigue, nausea and vomiting.
Patients with diabetes are prone to developing infections of the bladder, skin, and vaginal areas.
Fluctuations in blood glucose levels can lead to blurred vision. Extremely elevated glucose levels can lead to lethargy and coma.
The fasting blood glucose (sugar) test is the preferred way to diagnose diabetes. It is easy to perform and convenient. After the person has fasted overnight (at least 8 hours), a single sample of blood is drawn and sent to the laboratory for analysis. This can also be done accurately in a doctor's office using a glucose meter.
Normal fasting plasma glucose levels are less than 100 milligrams per deciliter (mg/dl).
Fasting plasma glucose levels of more than 126 mg/dl on two or more tests on different days indicate diabetes.
A random blood glucose test can also be used to diagnose diabetes. A blood glucose level of 200 mg/dl or higher indicates diabetes.
When fasting blood glucose stays above 100mg/dl, but in the range of 100-126mg/dl, this is known as impaired fasting glucose (IFG). While patients with IFG do not have the diagnosis of diabetes, this condition carries with it its own risks and concerns, and is addressed elsewhere.
The oral glucose tolerance test
Though not routinely used anymore, the oral glucose tolerance test (OGTT) is a gold standard for making the diagnosis of type 2 diabetes. It is still commonly used for diagnosing gestational diabetes and in conditions of pre-diabetes, such as polycystic ovary syndrome. With an oral glucose tolerance test, the person fasts overnight (at least eight but not more than 16 hours). Then first, the fasting plasma glucose is tested. After this test, the person receives 75 grams of glucose (100 grams for pregnant women). There are several methods employed by obstetricians to do this test, but the one described here is standard. Usually, the glucose is in a sweet-tasting liquid that the person drinks. Blood samples are taken at specific intervals to measure the blood glucose.
For the test to give reliable results:
the person must be in good health (not have any other illnesses, not even a cold).
the person should be normally active (not lying down, for example, as an inpatient in a hospital), and
the person should not be taking medicines that could affect the blood glucose.
For three days before the test, the person should have eaten a diet high in carbohydrates (200-300 grams per day).
The morning of the test, the person should not smoke or drink coffee.
The classic oral glucose tolerance test measures blood glucose levels five times over a period of three hours. Some physicians simply get a baseline blood sample followed by a sample two hours after drinking the glucose solution. In a person without diabetes, the glucose levels rise and then fall quickly. In someone with diabetes, glucose levels rise higher than normal and fail to come back down as fast.
People with glucose levels between normal and diabetic have impaired glucose tolerance (IGT). People with impaired glucose tolerance do not have diabetes, but are at high risk for progressing to diabetes. Each year, 1%-5% of people whose test results show impaired glucose tolerance actually eventually develop diabetes. Weight loss and exercise may help people with impaired glucose tolerance return their glucose levels to normal. In addition, some physicians advocate the use of medications, such as metformin (Glucophage), to help prevent/delay the onset of overt diabetes.
Recent studies have shown that impaired glucose tolerance itself may be a risk factor for the development of heart disease. In the medical community, most physicians are now understanding that impaired glucose tolerance is nor simply a precursor of diabetes, but is its own clinical disease entity that requires treatment and monitoring.
Evaluating the results of the oral glucose tolerance test
Glucose tolerance tests may lead to one of the following diagnoses:
Normal response: A person is said to have a normal response when the 2-hour glucose level is less than 140 mg/dl, and all values between 0 and 2 hours are less than 200 mg/dl.
Impaired glucose tolerance: A person is said to have impaired glucose tolerance when the fasting plasma glucose is less than 126 mg/dl and the 2-hour glucose level is between 140 and 199 mg/dl.
Diabetes: A person has diabetes when two diagnostic tests done on different days show that the blood glucose level is high.
Gestational diabetes: A woman has gestational diabetes when she has any two of the following: a 100g OGTT, a fasting plasma glucose of more than 95 mg/dl, a 1-hour glucose level of more than 180 mg/dl, a 2-hour glucose level of more than 155 mg/dl, or a 3-hour glucose level of more than 140 mg/dl.
Posted on :
12:17 AM
| By :
Biochemistry Den
| In :
Diabetes
• Home blood sugar (glucose) testing is an important part of controlling blood sugar. One important goal of diabetes treatment is to keep the blood glucose levels near the normal range of 70 to 120 mg/dl before meals and under 140 mg/dl at two hours after eating.
Blood glucose levels are usually tested before and after meals, and at bedtime. The blood sugar level is typically determined by pricking a fingertip with a lancing device and applying the blood to a glucose meter, which reads the value. There are many meters on the market, for example, Accu-Check Advantage, One Touch Ultra, Sure Step and Freestyle.
Each meter has its own advantages and disadvantages (some use less blood, some have a larger digital readout, some take a shorter time to give you results, etc). The test results are then used to help patients make adjustments in medications, diets, and physical activities.
• There are some interesting developments in blood glucose monitoring. Currently, at least three continuous glucose sensors are approved in the United States (Dexcom, Medtronic and Navigator). The new continuous glucose sensor systems involve an implantable cannula placed just under the skin in the abdomen or in the arm.
This cannula allows for frequent sampling of blood glucose levels. Attached to this is a transmitter that sends the data to a pager-like device. This device has a visual screen that allows the wearer to see, not only the current glucose reading, but also the graphic trends. In some devices, the rate of change of blood sugar is also shown. There are alarms for low and high sugar levels. Certain models will alarm if the rate of change indicates the wearer is at risk for dropping or rising blood glucose too rapidly.
The Medtronic version is specifically designed to interface with their insulin pumps. However, at this time the patient still must manually approve any insulin dose (the pump cannot blindly respond to the glucose information it receives, it can only give a calculated suggestion as to whether the wearer should give insulin, and if so, how much). All of these devices need to be correlated to fingersticks for a few hours before they can function independently. The devices can then provide readings for 3-5 days.
• Diabetes experts feel that these blood glucose monitoring devices give patients a significant amount of independence to manage their disease process; and they are a great tool for education as well. It is also important to remember that these devices can be used intermittently with fingersticks.
For example, a well-controlled patient with diabetes can rely on fingerstick glucose checks a few times a day and do well. If they become ill, if they decide to embark on a new exercise regimen, if they change their diet and so on, they can use the sensor to supplement their fingerstick regimen, providing more information on how they are responding to new lifestyle changes or stressors.
This kind of system takes us one step closer to closing the loop, and to the development of an artifical pancreas that senses insulin requirements based on glucose levels and the body's needs and releases insulin accordingly - the ultimate goal.
• Hemoglobin A1c (A1c)
• To explain what an hemoglobin A1c is, think in simple terms. Sugar sticks, and when it's around for a long time, it's harder to get it off. In the body, sugar sticks too, particularly to proteins. The red blood cells that circulate in the body live for about three months before they die off. When sugar sticks to these cells, it gives us an idea of how much sugar is around for the preceding three months. In most labs, the normal range is 4%-5.9 %. In poorly controlled diabetes, its 8.0% or above, and in well controlled patients it's less than 7.0% (optimal is <6.5%).>
Biochemistry is the fascinating chemical language of the science. There are some downloads have given to this week. just click and download the books. Christmas & New Year Special
0